Double Flanged Lined & Jacketed Steel Dip Pipe
- Item Number:
- 1
- Description:
- Double Flanged Lined & Jacketed Steel Dip Pipe
- Flange Nominal Tube Size (in):
- 1/2 (Note 1)
- PTFE Jacket OD (OD1) (in):
- 1
- PTFE Liner ID (ID1) (in):
- 7/16
- PTFE Seal OD Minimum (OD2) (in):
- 1-1/4
- Mounting Flange Seal OD Minimum (OD3) (in):
- See Note 5
- Steel Tube Thickness (in):
- 0.109
Product Notes
- As shown here, the PART NUMBER (DDF-NS-MF-L1) defines the series (first three characters), the nominal tube and connecting flange size NS, the mounting (or nozzle) flange size MF, and the insertion length L1. Use a decimal number to indicate NS. Then, replace MF with the decimal number to indicate the nominal size of the mounting flange and replace L1 with the insertion length in inches.
- For example, a 1-1/2” Double-Flange Dip Pipe with a 4” mounting flange x 60” insertion length would be DDF-1.5-4-60
- When used in a 1” nozzle, fits schedule 40 or thinner wall nozzles only.
- When used in a 1-1/2” nozzle, fits schedule 40 or thinner wall nozzles only.
- This size used with 2” nozzles only and fits schedule 40 or thinner wall nozzles only.
- This size used with 3-3/4” nozzles only and fits schedule 40 or thinner wall nozzles only.
- Click here to reference tables showing standard dimensions and mounting flange seal diameters.
- Standard flanges have ANSI Class 150 drilling. Class 300 and other sizes available.
- Standard tolerance on inserted length is ± 1/2”. Closer tolerances available, contact factory.
- Standard distance (L2) between flange sealing faces is 5”. Spacing is increased when a reinforcing collar is used. To order non-standard spacing, contact the factory.
- Most dimensions are governed by connecting flange size as shown in the Standard Dimension Table.
- Maximum standard overall length is 16 feet. For longer lengths, contact factory.
- For service conditions exceeding 350 F°, or 150 PSI, or vacuum service, contact factory.
- Vent hole can be optionally fitted with a 1/4" half-coupling.
- Links to Product Literature such as Installation Instructions can be found below the following table.
All Sizes
Click a row to load CAD and details above.
| Mounting Flange Seal OD Minimum (OD3) (in) |
|---|
| See Note 5 |
| Item # | Flange Nominal Tube Size (in) | PTFE Jacket OD (OD1) (in) | PTFE Liner ID (ID1) (in) | PTFE Seal OD Minimum (OD2) (in) | Steel Tube Thickness (in) |
|---|---|---|---|---|---|
| 1Request Info | 1/2 (Note 1) | 1 | 7/16 | 1-1/4 | 0.109 |
| 2Request Info | 3/4 | 1-1/4 | 5/8 | 1-9/16 | 0.113 |
| 3Request Info | 1 (Note 2) | 1-1/2 | 3/4 | 1-7/8 | 0.179 |
| 4Request Info | 1-1/2 (Note 3) | 2 | 1 | 2-11/16 | 0.140 |
| 5Request Info | 1-1/2 | 2-1/4 | 1-1/8 | 2-11/16 | 0.200 |
| 6Request Info | 2 | 2-3/4 | 1-5/8 | 3-7/16 | 0.218 |
| 7Request Info | 3 | 3-3/4 | 2-1/2 | 4-5/8 | 0.250 |
| 8Request Info | 3 (Note 4) | 3-15/16 | 2-1/2 | 4-5/8 | 0.300 |
| 9Request Info | 4 | 5-1/8 | 3-1/2 | 5-15/16 | 0.337 |